of 764
 
Chapter 30
30-54 Command Reference Guide for the Avaya P580 and P882 Multiservice Switches, v6.1
set utilization high-threshold
Command Mode Global Configuration.
Description Sets the high utilization threshold at which the switch generates a an event.
You can set a high utilization threshold for the CPU, forwarding engines on
80-series media modules, or forwarding engine on the supervisor module.
The default setting for the utilization threshold is 95 percent. Clearing the
utilization threshold resets it to 95 percent, its default setting.
For the switch to generate events when the high-utilization threshold is
exceeded, event logging must be enabled for utilization monitoring. To
enable event logging for utilization monitoring, use the set utilization
threshold-event command.
Syntax
To Configure: set utilization high-threshold {cpu | FIRE | FORE}
<utilization-percent>
To Restore
Default:
clear utilization high-threshold {cpu | FIRE | FORE}
Table 30-35. Keywords, Arguments, and Options
Name Definition
cpu Sets the high threshold for CPU utilization.
100% CPU utilization is the total capacity of
the supervisor module to forward slow path
traffic. When 100% utilization is reached, the
performance of the switch may degrade.
FIRE Sets the high threshold for utilization of the
forwarding engines on 80-series media
modules.
100% FIRE utilization is the total capacity of
the forwarding engines on 80-series media
modules to forward in band traffic. When
100% utilization is reached, the performance
of the switch may degrade.
1 of 2