of 764
 
Chapter 18
18-4 Command Reference Guide for the Avaya P580 and P882 Multiservice Switches, v6.1
set port internal-error-shutdown
Command Mode Global Configuration.
Description Enables or disables internal error detection and recovery (IEDR) on a port
or ports
Syntax
Sample Output The following example enables IEDR on all ports on the module in slot 3.
(configure)# set port internal-error-shutdown 3 enable
Systems P550R, P580, P880, and P882.
To Enable: set port internal-error-shutdown {<mod-num> | <mod-
swport-spec> | all-ports} enable
To Disable: set port internal-error-shutdown {{<mod-num> | <mod-
swport-spec>}| all-ports} disable
Table 18-2. Parameters, Keywords, Argument
Name Definition
{<mod-num> | <mod-
swport-spec>}
The slot number of the module, and, either port
number, or range of port numbers. Enter the port
ranges in the format Px-Py. For example:
To specify port 1 on the module in slot 3, enter
3/1.
To specify ports 1 through 5 on the module in
slot 3, enter 3/1-5.
all-ports Enables or disables IEDR on all ports on all modules in
the switch.