Document No. 10-300090, Issue 1 18-5
NEDR and IEDR
set port network-error-detection
Command Mode Global Configuration.
Description Configure network error detection and recovery (NEDR) for a port or ports.
Syntax
To Enable: set port network-error-detection <mod-port-range> [action
{notify | disable-port}] [rising-threshold <rising-threshold-
value>] [falling-threshold <falling-threshold-value>]
[interval <interval seconds>]
To Disable: network-error-detection {<mod-port-range> | all} action
off
Table 18-3. Parameters, Keywords, Argument
Name Definition
<mod-port-range> The slot number of the module, and, either port number,
or range of port numbers. Enter the port ranges in the
format Px-Py. For example:
To specify port 1 on the module in slot 3, enter 3/1.
To specify ports 1 through 5 on the module in slot
3, enter 3/1-5.
all Disables NEDR on all ports on all modules in the switch.
all can be used only with off.
action {notify |
disable-port | off}
Action that NEDR performs when the rate of errors
exceeds the threshold. The options are:
notify - Logs the event in the event log
disable-port - Disables the port and logs the event in the
event log.
Note: A port will be disabled if the rate of errors equals
or exceeds the threshold. Make sure a redundant
protocol is configured.
off - Disables NEDR on the port or ports that you specify.
The default setting is notify.
1 of 2