Document No. 10-300090, Issue 1 21-31
Port
Sample Output The following command sets NEDR on ports 1-5 on module 3.
(configure)# set port network-error-detection 3/1-5
Systems P550R, P580, P880, and P882.
<rising-threshold
value>
The rising threshold.
The number of CRC errors that triggers NEDR to log an
event in the event log or disable the port. The default
setting is 100 (minimum is 1; maximum is 65535).
Note: If you set the rising threshold value and the falling
threshold value close together, events may be
logged more often if the Notify option is
selected.
<falling-threshold
value>
The falling threshold.
After exceeding the rising threshold, NEDR does not log
another event in the event log until the rate of CRC errors
falls below the falling threshold and then exceeds the
rising threshold again. The default setting is half the
rising threshold value (minimum is 0; maximum is
65535).
Note: If you set the rising threshold value and the falling
threshold value close together, events may be
logged more often if the Notify option is
selected.
<interval-seconds> How often NEDR checks the number of errors occurring
against the thresholds. Enter a number of seconds.
The default setting is 2 seconds (minimum is 1;
maximum is 65535).
Table 21-26. Parameters, Keywords, Argument