Document No. 10-300090, Issue 1 21-39
Port
set port remote-fault-detect
Command Mode Global Configuration.
Description Enables or disables remote fault detections for gigabit ports. Remote fault
detection makes it possible for a Gigabit port at one end of a link to signal
status to the other end of the link, even if it does not have an operational
receive link.
* Note: Auto-negotiation and remote fault detection can not be enabled
at the same time. Auto-negotiation must be disabled to enable
remote fault detection. When auto-negotiation is enabled,
remote fault detection is automatically disabled.
Syntax
Sample Output The following example enables remote fault detection in gigabit ports 1 and
2 on the module in slot 3 of an Avaya Multiservice switch.
(configure)# set port remote-fault-detect 3/1,3/2 enable
Port remote fault detection enable set: 3/1,3/2
Systems P550R, P580, P880, and P882.
To Enable: set port remote-fault-detect {<mod-num> | <mod-port-
range>}[...,{<mod-num> | <mod-port-range>}] enable
To
Disable:
set port remote-fault-detect {<mod-num> | <mod-port-
range>}[...,{<mod-num> | <mod-port-range>}] disable
Table 21-33. Parameters, Keywords, Arguments
Name Definition
<mod-num> Specifies the number of the module where the ability to
detect remote link errors for each gigabit port on the
module is to be set.
<mod-port-range> Specifies a port or a range of gigabit ports whose ability to
detect remote link errors are enabled or disabled.