Document No. 10-300090, Issue 1 31-3
Temperatures
set temperature (shutdown)
Command Mode Global Configuration.
Description Sets the shutdown temperature for a specific component of the switch. The
default setting for the CPU sensor is
100° C. The default setting for all other
components is
65°C.
Syntax set temperature {supervisor-slot | backplane-sensor | cpu-sensor | probe}
shutdown <temperature>
Sample Output The following example sets the CPU sensor shutdown temperature to 95°
(Celsius).
(configure)# set temperature shutdown cpu-sensor 95
Systems P550R, P580, P880, and P882.
Table 31-2. Parameters, Keywords, Arguments
Name Definition
{supervisor-slot |
backplane-sensor | cpu-
sensor | probe}
Indicates which component of the switch you are
setting the shutdown temperature for.
Note: After you change the temperature settings for
the active supervisor, you must synchronize the
active and standby supervisors to copy the
temperature settings to the standby supervisor.
shutdown Shutdown is a required parameter and indicates that
the shutdown limit temperature is being set.
<temperature> Temperature is a required parameter and when the
switch measures this value on this component, it shuts
itself down to prevent either inconsistent behavior or
damage to itself or surrounding equipment.
The command checks the entered temperature value
and ensures that the temperature being set is not above
127, and not below -128 degrees, the backplane sensor
and supervisor are not below 60 and not above 127
degrees, and the CPU sensor is not below 85 and not
above 127 degrees.